Input voltage: | 0.9~ 1.1pu; LVRT 0pu(150ms), 0.2pu(625ms) |
Frequency: | 50/60Hz; Allow short-term fluctuations |
Starting power: | ±0.005Mvar |
Compensation current resolution: | 0.5A |
Response time: | <5ms |
Power loss: | <0.8% |
Company Info. |
WindSun Science & Technology Co.,Ltd. |
Verified Supplier |
View Contact Details |
Product List |
33kV Static Var Generator(SVG) – Outdoor type | ||||
Voltage class(kV) | Rated capacity(Mvar) | Dimension W*D*H(mm) | Weight(kg) | Reactor type |
33 | 5.0~30.0 | 6058*2438*2896 | 19000~23000 | Air core reactor |
30.0~100.0 | 12192*2438*2896 | 25000~50000 |
Benefits
Correct power factor, stabilize voltage, reduce grid impact, and prevent fines and failures caused by power quality issues.
Reduce line losses and optimize inverter efficiency to improve the power output of photovoltaic (PV) stations.
Suppress harmonics, improve power quality, reduce equipment damage, extend equipment lifespan, and lower maintenance costs.
In areas with limited grid capacity, enhance the grid integration capability of PV stations to increase power generation.
Technical Specifications
Name | Specification |
Rated voltage | 33kV±10% |
Assessment point voltage | 33kV±10% |
Input voltage | 0.9~ 1.1pu; LVRT 0pu(150ms), 0.2pu(625ms) |
Frequency | 50/60Hz; Allow short-term fluctuations |
Output capacity | ±0.1Mvar~±200 Mvar |
Starting power | ±0.005Mvar |
Compensation current resolution | 0.5A |
Response time | <5ms |
Overload capacity | >120% 1min |
Power loss | <0.8% |
THDi | <3% |
Control power | 380VAC, 220VAC/220VDC |
Reactive power regulation mode | Capacitive and inductive automatic continuous smooth adjustment |
Communication interface | Ethernet, RS485, CAN, Optical fiber |
Communication protoco | Modbus_RTU, Profibus, CDT91, IEC61850- 103/104 |
Running mode | Constant device reactive power mode, constant assessment point reactive power mode, constant assessment point power factor mode, constant assessment point voltage mode and load compensation mode |
Parallel mode | Multi machine parallel networking operation, multi bus comprehensive compensation and multi group FC comprehensive compensation control |
Protection | Bus overvoltage, bus low voltage, SVG overcurrent, drive fault, module overvoltage, overcurrent, overtemperature and communication fault; Protection input interface, protection output interface, abnormal system power supply and other protection functions. |
Fault handling | Adopt redundant design to meet N-2 operation |
Cooling mode | Water cooling/Air cooling |
IP degree | IP30(indoor); IP54(outdoor) |
Storage temperature | -40℃~+70℃ |
Running temperature | -35℃~ +40℃ |
Humidity | <90% (25℃), no condensation |
Altitude | <=2000m (above 2000m customized) |
Earthquake intensity | Ⅷ degree |
Pollution level | Grade IV |
Installation
Installation | Cooling method | Connection |
Indoor | Air cooling | Direct-Connected Type |
Outdoor | Water cooling | Transformer-Coupled Type |
Offer installation support and on-site commissioning by experienced
engineers.
Starting from the date of successful commissioning, the product is
covered by a one-year quality warranty.
With over 50 years of R&D experience since 1970, we are fully
capable of meeting the grid standards of various countries.
For the past 20 years, we have been dedicated to the research,
development, and manufacturing of SVG products. With steadily
increasing customer satisfaction, we are confident in our ability
to solve your power quality challenges.
Production Base: North of the middle section of Jincheng Road, Economic Development Zone, Wenshang County
R&D Center: No. 21, Gongye North Road, Baoshan Sub-district,
Licheng District, Jinan City
Email: overseas@fengguang.com
Website: http://www.fengguang.
![]() |