Category: | Reusable SpO2 Sensor |
Connector Distal: | Square, 11-pin, keyed connector |
Latex-free: | Yes |
Company Info. |
Med Accessories Technology Dongguan Co., Ltd. |
Verified Supplier |
View Contact Details |
Product List |
GE Marqutte Oximax Reusable Spo2 Sensors 11pin neonatal silicone wrap spo2 sensor
Manufacturer | Model |
---|---|
GE Healthcare > Corometrics | 128, 250, 250cx, 259, TRAM 450SL |
GE Healthcare > Critikon > Dinamap | Carescape B650, Carescape B850, Carescape V100 |
GE Healthcare > Marquette | Dash 2500, Dash 3000, Dash 4000, Dash 5000, Dash Series, Eagle, PDM
Module, Procare B40, SOLAR, Solar 8000, Solar 8000M, TRAM Modular,
Tram 451, i/9500, x50SL Series |
Warranty/Liability information:
Med Accessories provides a one-year warranty against defects in
material and/or workmanship for their sensors, starting from the
date of purchase. This warranty covers any issues that arise due to
manufacturing defects. However, it does not cover damage or
breakage resulting from abusive use or negligent care of the
sensor. Med Accessories guarantees that their equipment meets the
specifications of the current safety and performance standards that
are applicable to it.
Additionally, the following warnings should be noted:
1.Sensors designed for specific monitors: The sensors are
specifically designed to be used with certain monitors. It is the
responsibility of the operator to ensure compatibility between the
monitor, probe, and cable before using them together. Using
incompatible components can result in degraded accuracy and
performance.
2.Accuracy assessment: It is advised not to assess the accuracy of
the sensor using a functional tester or oximetry simulator.
Instead, refer to the operation instructions of the equipment and
related accessories for appropriate accuracy assessment methods.
3.Consult operation instructions: Before operating the equipment,
it is important to consult the operation instructions for both the
equipment and related accessories. This will help ensure
compatibility and proper usage.
4.Interference from portable/mobile RF communications equipment:
Keep in mind that portable and mobile RF communications equipment
can potentially affect the operation of the equipment. Take
necessary precautions to minimize interference.
5.Disposal compliance: When disposing of the sensor, it should be
done in accordance with the local regulations regarding proper
disposal methods.
It is important to adhere to the warranty, liability terms, and
warnings provided by Med Accessories to ensure proper usage,
accurate results, and compliance with safety regulations.
Reminder:
When selecting the SpO2 sensor, please consider the following points:
Compatibility with patient monitor socket: Ensure that the SpO2 sensor connector is compatible with the socket on your patient monitor. Check whether it requires a 5-pin or 6-pin connector to ensure a proper fit.
Patient terminal type: Determine whether the sensor uses snap or clip patient terminals. Choose the appropriate type based on your preference and the compatibility with your patient monitor.
Appropriate sensor for the intended user: Verify that the sensor is suitable for the intended patient population. Different sensors are designed for adults, neonates, or other specific age groups. Select the sensor that corresponds to the specific patient category to ensure accurate readings and proper fit.
By carefully considering these points, you can ensure that you select the correct SpO2 sensor that is compatible with your patient monitor, uses the desired patient terminal type, and is appropriate for the intended patient population.
![]() |