Brand Name: Aolittel
Model Number: BTC1400B
Certification: UL,cUL
Place of Origin: CHINA
MOQ: 1000 Pieces
Price: Negotiable
Payment Terms: T/T,Paypal
Supply Ability: 1,000,000 Pieces Per Month
Delivery Time: 7-10 Workdays
Packaging Details: Bulk,500pcs/bag
Fuse Type: Ceramic Fuse
Current Rating: 4A
Voltage Rating AC: 125VAC
Fuse Size: 5 mm x 20 mm
Blown: Time Delay / Slow Blow
Mounting Style: Holder / Clip
Body Style: Cylindrical
Interrupt Rating: 1.5KA
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

High Breaking Capacity 5x20mm Ferrule Slow Blow Time Delay Ceramic Tube Fuse Link 4A 125VAC For White Goods


High Breaking Capacity 5x20mm Ferrule Slow Blow Time Delay Ceramic Tube Fuse Link 4A 125VAC For White Goods


Description


5×20mm Time-Lag surge withstand ceramic body cartridge fuse designed to IEC specification,Standards:In accordance with IEC60127-1, IEC60127-3, GB9364.1, GB9364.3.


Product features


• Time-delay high breaking capacity
• 0.1 A to 30 A current ratings
• Ceramic tube, nickel plated brass end cap construction
• Halogen free, RoHS compliant, lead free

• Designed to International (IEC ) Standards for use globally

• High breaking capacity

• Meets the IEC 60127-2, Sheet 5 specification for Time-Lag fuses


Applications


Used as supplementary protection in appliance or utilization equipment to provide individual protection for components or internal circuits.


Primary circuit protection:

• LED and general lighting

• LED/LCD televisions

• Appliances and white goods

• Printers and peripherals

• Test equipment

• Power supplies


___________________________________________________________Epoxy Coated Photocell 11mm Diameter Photoresistor Light Sensor GM11528 With Light Resistance 10-20 KOhm Download________


Certifications


Voltage Rating

Agency

Ampere Range

Agency File Number

250V/125V ACUR200mA ~ 10AE340427(JDYX2)
C-UR200mA ~ 10AE340427( JDYX8)

Specification


Part

No.

Ampere

Rating

Voltage

Rating

Max Voltage

Drop (mv)

I2TMelting

Integral(A2.S)

Agency Approvals

ULcUL
BTC0100A100mA250V/125V7000-
BTC0125A125mA250V/125V5000-
BTC0160A160mA250V/125V4300-
BTC0200A200mA250V/125V3500-
BTC0250A250mA250V/125V2800-
BTC0315A315mA250V/125V2500-
BTC0400A400mA250V/125V2000-
BTC0500A500mA250V/125V18000.2
BTC0630A630mA250V/125V15000.3
BTC0750A750mA250V/125V14000.3
BTC0800A800mA250V/125V12000.4
BTC1100A1A250V/125V10000.6
BTC1125A1.25A250V/125V8000.8
BTC1150A1.5A250V/125V6001.0
BTC1160A1.6A250V/125V6001.2
BTC1200A2A250V/125V5003.4
BTC1250A2.5A250V/125V4007.2
BTC1300A3A250V/125V3508.5
BTC1315A3.15A250V/125V3509.2
BTC1350A3.5A250V/125V3509.2
BTC1400A4A250V/125V30014
BTC1500A5A250V/125V25025
BTC1600A6A250V/125V25025
BTC1630A6.3A250V/125V20064
BTC1700A7A250V/125V200-
BTC1800A8A250V/125V200-
BTC2100A10A250V/125V200-
BTC2120A12A250V/125V--
BTC2125A12.5A250V/125V--
BTC2160A16A250V/125V--
BTC2200A20A250V/125V--
BTC2250A25A250V/125V--
BTC2300A30A250V/125V--

Dimension (mm)


Without lead
With lead

NO.

Part Name

Material

1

Cap

Nickel Plated Brass

2

Body

Non-Transparent Ceramic Tube

3

Fuse element

Alloy

4

Filler

Silica

5

Lead wire

Tin Plated Copper


Operating Characteristics


% of Ampere Rating(In)

Blowing Time

100% * In4 hours Min
200% * In60 sec Max

Temperature Rerating Curve



Recommended Hand-Solder Parameters:


Solder Iron Temperature: 350° C +/- 5°C
Heating Time: 5 seconds max.
Note: These devices are not recommended for IR or Convection Reflow process.


Extra services


For the pigtailed fuse, please follow the recommendations below for axial lead forming and mounting into PCB:


Lead forming:
The distance C between cap flat surface and axial lead shall be greater than 1.0 mm.


PCB mounting:
The distance between PCB and fuse cap is recommended to be a minimum of 1.5 mm.



HOW TO IDENTIFY AND REPLACE A BLOWN FUSE


Step 1: Disconnect DeviceIn this step you will need to disconnect device that isn't working
It's not so hard you just need to disconnect plug that goes to main socket
I would also recommend to power off device first
NEVER OPEN DEVICE THAT IS STILL CONNECTED TO MAIN!
Step 2: Locating FuseFuses are usually at device input so look near power socket
When you pulling fuse out pull it gently so you wont damage fuse or some components
Step 3: Testing Fuse
If you have glass fuse you can easily see if fuse is burned or not
For ceramic types you will need continuity checker/multimetermmeter
For continuity checker
Put fuse on black and red lead and if you hear beep than your fuse is ok, if theres no beep fuse is burned
For multimetermmeter
Set multimeter to ohm setting (closest to 1Ω) and put one lead on each end of the fuse and look at the display
If the meter shows a less than 1Ω then the fuse should be okay, if it show that theres no connection (on my multimeter is 1 on left side) then fuse is burned
Step 4: Buying New FuseCheck one cap on fuse,PCB or manual for fuse ratings
There should be written something like : T2A250V, F1A250V that's fuse rating
T is for slow blow fuse and F for fast blow fuse
2A or 1A is Amperage rating its usually just number and A
250V is Voltage rating its number and V
And then just measure the size of fuse
In small electrical device is usually 5x20mm
There are 5x20mm, 5x15mm, 6.3x32mm, 3.6x10mm, 5x25mm and 10x38mm

Buy High Breaking Capacity 5x20mm Ferrule Slow Blow Time Delay Ceramic Tube Fuse Link 4A 125VAC For White Goods at wholesale prices
Send your message to this supplier
 
*From:
*To: Aolittel Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0