Sign In | Join Free | My tjskl.org.cn
tjskl.org.cn
Products
Search by Category
Home > Switching Power Supply >

Custom 50W Output Switcher Power Supply 220V / 110V Overload Protection

Categories Switching Power Supply
Brand Name: Winston
Model Number: T-50
Certification: CE
Place of Origin: China.Zhejiang
MOQ: 10 piece
Price: Negotiable
Payment Terms: T/T, Western Union, MoneyGram,Paypal
Supply Ability: 10000Piece / Month
Delivery Time: 3-7 days after Payment
Packaging Details: Export standard carton box
Warranty: 2 Years
OEM: YES
ODM: YES
Dimensions: 129*98*38mm
Condition: Original New
Output Frequency: 47-63HZ
Input Voltage: 110V/220V
Output Power: 50W
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Custom 50W Output Switcher Power Supply 220V / 110V Overload Protection

    Custom 50W Output Switcher Power Supply 220V / 110V Overload Protection


    Description:


    1 . Competitived price and high reliability

    2 . AC input power suitable for the world

    3 . High efficiency and low operation temperature

    4 . With short-circuit and overload protection

    5 . Installed with EMI filter, minimum wave

    Specification:


    Model

    Specification

    T-50A

    T-50B

    T-50C

    T-50D

    CH1

    CH2

    CH3

    CH1

    CH2

    CH3

    CH1

    CH2

    CH3

    CH1

    CH2

    CH3

    DC output voltage

    5V

    12V

    -5V

    5V

    12V

    -12V

    5V

    15V

    -15V

    5V

    15V

    24V

    Output voltage error (Note2)

    ±2%

    ±5%

    ±5%

    ±2%

    ±5%

    ±5%

    ±2%

    ±5%

    ±5%

    ±2%

    ±6%

    ±6%

    Rated output current

    7A

    1A

    1A

    5A

    1A

    1A

    4A

    1A

    1A

    3A

    1A

    1A

    Output current range

    0.6-7A

    0.2-1A

    0.2-1A

    0.6-5A

    0.2-1A

    0.2-1A

    0.6-4A

    0.2-1A

    0.2-1A

    0.6-4A

    0.2-2A

    0.2-1A

    Wave and noise(Note3)

    100mV

    100mV

    100mV

    100mV

    100mV

    100mV

    100mV

    100mV

    100mV

    50mV

    120mV

    120mV

    Inlet stability(Note4)

    ±0.5%

    ±0.5%

    ±0.5

    ±0.5%

    ±0.5%

    ±0.5

    ±0.5%

    ±0.5%

    ±0.5

    ±0.5%

    ±1%

    ±1%

    Load stability(Note5)

    ±1%

    ±4%

    ±4%

    ±1%

    ±4%

    ±4%

    ±1%

    ±4%

    ±4%

    ±1%

    ±5

    ±5%

    DC output power

    52W

    49W

    50W

    51W

    Efficiency

    66%

    69%

    71%

    72%

    Adjustable range for DC voltage

    CH1+10,-5%

    CH1+10,-5%

    CH1+10,-5%

    CH1+10,-5%

    AC input voltage range

    85132VAC/170264VAC selected by switch 4763Hz;240370VDC

    Input current

    1.6A/115V 0.8A/230V

    AC impulse current

    Cold-start current 20A/115V 40A/230V

    Leakage current

    <0.5A/240VAC

    Overload protection

    105%150% TypePULSING HICCUP SHUTDOWN ;Reset auto recovery

    Over-voltage protection

    .

    High-temperature protection

    .

    Temperature coefficient

    ±0.03%(050) ON+5V OUTPUT

    Setup rise hold up time

    200ms,50ms,16ms

    Vibration

    10500Hz,2G 3AXES 10min./1cycle,Period for 60min,Each axes

    Withstand voltage

    Input and output interval1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC

    Isolation resistance

    Input and output interval,Input and enclosure,Output and enclosure500VAC/100M Ohms

    Working temperature and humidity

    -10+60,20%90%RH

    Store temperature and humidity

    -20+85,10%95%RH

    Overall dimension

    159*97*38mm

    Weight

    0.54Kgs

    Safety standards

    Meet UL1012 requirement(Not apply for the mark)

    EMC standards


    Note:

    1. The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity
    2. Error,include the setting error, line stability and load stability.(Note:5)
    3. Wave test:adoptingA12double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
    4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
    5. Load stability test: The load is from 0% to 100%,others 60%.
    6. C2311must be knocked down.


    Product Picture


    Our Services
    • Customized Samples are acceptable
    • Accept different payment methods, such as T/T, L/C, Western Union, Escrow to meet your different financial requirements
    • Welcome and accept 100% customers factory inspection before the production
    • Supply skills training including product basic knowledge, installation, operation, maintenance skills training for the local people
    • We provide 7 days 24 hours service!

    PS: If you can't find the exact type of your product.Please don't rush to go away.Contact me and your questions will be replied ASAP.Thank you for your time.


    Buy Custom 50W Output Switcher Power Supply 220V / 110V Overload Protection at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: YUEQING WINSTON ELECTRIC CO.,LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0