Brand Name: Pearl Electric Co.,Ltd.
Model Number: PEO-S, S9~13
Certification: KEMA, CE, CCC, ISO9001
Place of Origin: China
MOQ: 1 unit
Price: USD/RMB
Payment Terms: T/T, L/C
Supply Ability: 4000 units per year
Delivery Time: 35~50days ex-work
Packaging Details: Seaworthy wooden packing
Capacity: 30kVA~10MVA or Customized
Rated H. V.: 30 kv or Customized
Rated L. V.: 0.4kv or Customized
Vector Group: Dyn11 or Customized
Impedence: 4%-6% or Customized
Cooling: ONAN/ONAF or Customized
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    IP30 - 60 Oil Type Pad Mounted Distribution Transformer 30 KV - Class


    Clean Energy , 22 kV - Class , Pad Mounted , Oil - Immersed Transformer , Wind Power Farm


    Pad-mounted Transformer Introduction


    General Descriptions


    The main purpose of this manual is for supporting transformer assembly/installation,
    operation and usage by engineering personnel or technicians.
    The transformer described in this manual is the completely insulated and hermetically sealed
    three-phase distribution pad-mounted transformer, which is suitable for the three-phase power
    distribution system of 10kV rated voltage and satisfies requirements specified in China national
    standard.


    Specifications:
    Rated H.V.:20 (20.5, 22)kV, ±2×2.5%
    Vector GroupDyn11/Yyn0/Yzn11
    Rated L.V.:0.4kV
    Capacity:30~2500
    No-load Loss:130~3200kW
    Load Loss600~20200kW
    No-load Current:2.1~0.5%
    Impedance Voltage:4/4.5/5.5%
    Tap-changingOn-load Tap-changing
    Reference StandardsIEC60076
    Notes: The above specifications may be customized according to customer's requirement.


    Functions and Advantages:


    1. High safety protection

    2. Complete functions and reliable performance

    3. Flexible structure

    4.Convenient maintenance

    5. Low power consumption and energy saving

    6. Low-noise

    7. High protection level and weathering resistance

    8. High mechanical strength and leakage-free



    Unpacking and Accepting
    Please check whether there is any damage, distortion and crack on the transformer and its
    components. With reference to the shipping list or packing list, check the accessories and special
    tools. Only after the inspection is finished and the result is acceptable can the installation be
    carried out.


    Notices for installation:


    Before any system connection, be sure the transformer is earthed. The earthing terminal
    of the pad-mounted transformer should be a fixed and low-resistance earthing point. If
    the earthing resistance does not meet the requirement, resistance reduction measures
    should be adopted.


    Before system cabling, please clean all the bushings, bushing seats, terminal cabling
    seats and contacting point, to remove all the dust, oil pollution and foreign substances.

    During installation, please close the equipment door and lock it when there is no technician on duty.


    Installation Process


    Please refer to the following process for installation:
    Prepare the installation base---->lay the HV and LV cables---->equipment
    lifting---->equipment fixing---->equipment earthing---->HV and LV cable fixing
    (preliminarily)---->HV and LV cable phase process---->prepare elbow cable plug and LV
    terminal---->put the elbow cable plug (and lightning rod) into the bushing and connect the LV
    cables---->mount the fault indicator and electricity display---->mounting LV sub-assembly.


    Prepare the Installation Base


    The basis is composed of reinforced concrete base capable of holding the transformer, the
    manhole convenient for cable connections and equipment maintenance, cable support/rack or
    earthing sub-assembly. Fore more information about the basis preparation, please refer to the basis
    manufacturing instructions provided together with the equipment.


    Please be noted that:
    1) The basis should be made far from the flat bog area, to avoid water drenching.
    2) The base top should be located on a high place and 100~400mm above the ground.
    3) Cable supporting rack should be made on the basis and firmly fixed, with certain
    mechanical strength to avoid any shaking or loosing.
    4) The base should be of sufficient mechanical strength to prevent any sinking, which may
    cause equipment damage.
    5) The surface of the base should be on the same level and smooth. If necessary, please use
    level bar to check the base surface, thus to ensure no equipment distortion will happen
    due to poor base conditions. Un-even base surface may makes door opening difficult.
    6) The earthing resistance and earthing cross section should meet corresponding national
    standards, industrial standards and regulations specified by local power administration
    authority.